Post on 12-Nov-2015
description
PREGUNTA 2:Se har una comparacin entre los resultados obtenidos y los valores tericos para cada circuito respectivamente.
CIRCUITO 1:MALLAVALOR REAL (V)VALOR TEORICO (V)% DE ERROR
13.894.0213.258
24.0574.0210.895
34.0554.0210.845
CIRCUITO 2:
CASO 1 (Rv = 70.1 K)MALLAVALOR REAL (V)VALOR TEORICO (V)% DE ERROR
115.70615.560.938
215.715.560.899
315.715.560.899
415.53615.560.154
CASO 2 (Rv = 100.2 K)MALLAVALOR REAL (V)VALOR TEORICO (V)% DE ERROR
115.55715.560.019
215.5615.560
315.5615.560
415.39215.561.079
CIRCUITO 3:
CASO 1 (Rv = 69.9 K)MALLAVALOR REAL (V)VALOR TEORICO (V)% DE ERROR
112.7912.8240.265
211.2311.1160.01
311.2111.0881.1
41.7161.7080.468
51.7381.7360.115
60.0210.02825
CASO 2 (Rv = 74.4 K)MALLAVALOR REAL (V)VALOR TEORICO (V)% DE ERROR
112.8212.8670.365
211.2611.1680.823
311.2511.1530.869
41.7111.6990.706
51.7231.7140.525
60.0130.01513.33
CASO 3 (Rv = 100.7 K)MALLAVALOR REAL (V)VALOR TEORICO (V)% DE ERROR
112.9513.0470.743
211.4211.3860.298
311.4511.4260.21
41.6841.6611.384
51.6571.6212.22
60.0280.0430
PREGUNTA 5:Se resolver los circuitos con los valores medidos de las resistencias antes de realizar la experiencia; los cuales fueron usados en cada uno de los circuitos respectivamente.Los valores me muestran en las siguientes tablas respectivamente:
CIRCUITO 1:VOLTAJES (V)CORRIENTES (mA)
R115.9792.874
R24.0212.7
R32.0950.174
R40.2070.174
R51.7190.174
CIRCUITO 2:
CASO 1 (Rv = 70.1 K)VOLTAJES (V)CORRIENTES (mA)
R112.2732.207
R23.2872.207
R315.561.289
R44.443.718
Rv15.560.322
CASO 2 (Rv = 100.2 K)VOLTAJES (V)CORRIENTES (mA)
R112.3212.216
R23.2992.216
R315.6221.294
R44.3783.666
Rv15.6220.156
CIRCUITO 3:
CASO 1 (Rv = 69.9 K)VOLTAJES (V)CORRIENTES (mA)
R17.1761.291
R21.7081.147
R31.7360.144
R40.0280.024
R511.1161.123
Rv11.0880.168
CASO 2 (Rv = 74.4 K)VOLTAJES (V)CORRIENTES (mA)
R17.1331.283
R21.6991.141
R31.7140.142
R40.0150.013
R511.1681.128
Rv11.1530.15
CASO 3 (Rv = 100.7 K)VOLTAJES (V)CORRIENTES (mA)
R16.9531.251
R21.6611.116
R31.6210.134
R40.040.034
R511.3861.15
Rv11.4260.113