ACECO TI – SALA MODULAR
Líder em Infraestrutura para Data Centers na América Latina
![Page 2: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/2.jpg)
Data Center Container ACECO
Sala Modular DCMPF MF-60
![Page 3: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/3.jpg)
Sala Modular
Módulo Standard
![Page 4: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/4.jpg)
Data Center Modular Pre Fabricado
Ampliación que acompaña el crecimiento de TI
Amplicación de instalación en medida de lá
necesidad.
Desmontable, trasladable, y escalable a un área
mayor.
Autoportante, con estructura de vigas propia.
Construida de piso, paneles laterales,techo.
Grado de Protección IP66.
Iluminación Interior e Iluminación de Emergencia.
La puerta se integra a um sistema de control de
acceso.
Área Externa de 3.20m como mínimo..
4
![Page 5: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/5.jpg)
Modularidad y Flexibilidad
Módulo Doble Vertical
![Page 6: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/6.jpg)
Flexibilidad y Modularidad
Posibilita el montaje de acuerdo con la necesidad del cliente.
![Page 7: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/7.jpg)
Data Center Modular Pre Fabricado
![Page 8: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/8.jpg)
Integración.
![Page 9: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/9.jpg)
Data Center Modular Pré-fabricado
Ceiling Mounted
10 kW
17kW
Climatización
![Page 10: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/10.jpg)
Data Center Modular Pré-fabricado
In Row
10 kW
15KW
35 kW
De acuerdo a
demanda
Climatización
![Page 11: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/11.jpg)
Data Center Modular Pre-fabricado
Climatización - Combinada
![Page 12: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/12.jpg)
DATA CENTERS MODULARES PRÉ-FABRICADOS ACECO TI
MF-60
Opciones de Tamaño(pies) 20' 40' Medidas especiales
Capacidad (quantidad de racks) 7 17 De acuerdo con la necesidad
Potencia máxima (kW) 78 kW
240 kW
De acuerdo con la necesidad
Climatización Ceiling mounted, e In row rack
Protección contra agua y polvo – IP IP66
Acesso indebido (EN 1627/1630)
WK4
Impacto de escombros 300 joules
Explosión 200kj TNT a 40m
Resistencia al Fuego 60 minutos
Modular,transportable,escalable SI
Certificação Uptime (Tier I, II, III ou IV) Si (opcional) de acuerdo a proyecto
Leed – Selo verde Si (opcional) de acuerdo a proyecto
![Page 13: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/13.jpg)
Aplicación •Clientes que no poseen espacio
suficiente dentro de su edificio para
dedicar un área adecuada para TI.
• Clientes que desean transportar
su DC para otras localidades com
velocidad y poco impacto al edificio
y sus instalaciones.
•Periodo de retrofit de su Data
Center
•Período de obra de construcción
civil y/o remodelación del edificio.
![Page 14: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/14.jpg)
Normas Aplicables al DCMPF
![Page 15: 1. MEMORIA DESCRIPTIVA - SALA MODULAR DCMPF MF-60.pdf](https://reader030.fdocuments.co/reader030/viewer/2022020201/55cf8cf75503462b1390ca48/html5/thumbnails/15.jpg)
Empresa líder en infraestructura para Data Centers en América Latina
1 Data Center entregado cada 5 dias