Atencion de enfermeria con el niño con diarrea y deshidratacion
Deshidratacion Con Glicol
-
Upload
hermann2025 -
Category
Documents
-
view
205 -
download
6
Transcript of Deshidratacion Con Glicol
![Page 1: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/1.jpg)
DESHIDRATACION CON GLICOL
![Page 2: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/2.jpg)
CONTENIDO
LOS GLICOLES
EL PROCESO (DISEÑO Y PARAMETROS)
LOS EQUIPOS
LOS PROBLEMAS OPERACIONALES
![Page 3: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/3.jpg)
LOS GLICOLES
MUCHOS LIQUIDOS ABSORBEN AGUA, SIN EMBARGO POCOS CUMPLEN:
NO SOLIDIFICAN EN SOLUCIONES CONCENTRADAS
NO CORROSIVOS
NO FORMAN PRECIPITADOS CON HIDROCARBUROS
FACILMENTE REGENERABLES A ALTA CONCENTRACION
INSOLUBLES EN HIDROCARBUROS
ESTABLES EN PRESENCIA DE CO2, H2S
![Page 4: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/4.jpg)
C
H
OH
H
C
H
H
LOS GLICOLES
OH
O
CH2 OH CH2
CH2 OH CH2
CH2 CH2
CH2
O CH2 OH
CH2 O CH2 OH
ETILENGLICOL (EG)
DIETILENGLICOL (DEG)
TRIETILENGLICOL (TEG)
![Page 5: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/5.jpg)
EG DEG TEG Metanol
C2H6O2 C4H10O3 C8H18O5 CH3OHPeso Molecular 62,1 106,1 150,2 32,04T ebullición atm (oF/oC) 387 / 193 476 / 245 545 / 286 148 / 64,5
P vapor 77 oF/ 25oC, mmHg 0,12 < 0,01 < 0,01 120SG @ 77 oF (25 oC) 1,110 1,113 1,119 0,790SG @ 140 oF (60 oC) 1,085 1,088 1,092Freezing Point (oF / oC) 8 / -13 17 / -8 19 / -7 -144 / -98Visc @ 77 oF (25 oC), cP 16,5 28,2 37,3 0,52Visc @ 140 oF (60 oC), cP 4,7 7,0 8,8Cp @ 77 oF (25 oC),btu/lboF 0,58 0,55 0,53 0,60T descomposición (oF/oC) 329 / 165 328 / 164 404 / 206
LOS GLICOLES
![Page 6: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/6.jpg)
DESHIDRATACION CON GLICOL
VENTAJAS: SIMPLE
PROBADA
BAJO CAPEX
BAJO OPEX
CUMPLE ESPECIFICACIONES
DESVENTAJAS: LIMITADO A Dew Point > -40 oF (-40 oC)
CONTAMINACION DE SOLVENTE / PERDIDAS
ABSORCION DE AROMATICOS Y H2S
VENTEO A INCINERACION
![Page 7: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/7.jpg)
EL PROCESO
LC
LC
PC
LC
GAS HUMEDO
GAS SECO
GLICOL POBRE
GLICOL RICO
TANQUE FLASH
ACUMULADOR
REBOILER
VAPOR DE AGUA
![Page 8: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/8.jpg)
FACTORES DE DISEÑO Y EVALUACION
PARA EL DISEÑO Y EVALUACION DE UN SISTEMA DE GLICOL, DEBEN TOMARSE EN CUENTA LOS SIGUIENTES ASPECTOS:
LA MINIMA CONCENTRACION DE TEG EN LA SOLUCION POBRE AL ABSORBEDOR
LAS TASA DE CIRCULACION DE TEG PARA REMOVER EL AGUA
LA CANTIDAD (#) DE CONTACTO EN EL ABSORBEDOR PARA PRODUCIR EL “EQUILIBRIO”
![Page 9: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/9.jpg)
CONCENTRACION MINIMA DE GLICOL
SI GAS SATURADO SE COLOCA EN UNA CELDA CON GLICOL A ALTA CONCENTRACION, EL GLICOL ABSORBE EL AGUA HASTA EL EQUILIBRIO.
EL CONTENIDO DE AGUA EN EQUILIBRIO SE CONOCE COMO “DEW POINT DE EQUILIBRIO” (PUNTO DE ROCIO DE EQUILIBRIO).
![Page 10: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/10.jpg)
98,5 % Estándar
CONCENTRACION MINIMA DE GLICOL
![Page 11: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/11.jpg)
CONCENTRACION MINIMA DE GLICOL
UN CONTACTOR NO ES UNA CELDA. EXPERIMENTOS HAN DEMOSTRADO QUE EL PTO DE ROCIO ES 10-15 oF SUPERIOR AL IDEAL. ESTO SE CONOCE COMO “APPROACH”
1. SE DETERMINA EL CONTENIDO DE AGUA Y PTO DE ROCIO DE SALIDA DEL GAS
2. SE SUSTRAE EL “APPROACH”. SE OBTIENE Trocio REQUERIDO
3. SE ENTRA A LA GRAFICA CON T rocío de (2) Y T contactor
4. SE ESTABLECE MINIMA CONCENTRACION GLICOL POBRE
![Page 12: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/12.jpg)
CONCENTRACION MINIMA DE GLICOL
98,5 % ES LA MAXIMA CONCENTRACION DE TEG EN REGENERACION CONVENCIONAL A Patm - 400 oF.
PARA > % wt, CONSIDERE VACIO, STRIPPING U OTROS
SI % WT RESULTANTE < 98,5%, CONSIDERE 98,5%
![Page 13: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/13.jpg)
CAUDAL DE CIRCULACION DE TEG
LA MASA DE AGUA A RETIRAR
LA CONCENTRACION DE GLICOL POBRE
EL NUMERO DE ETAPAS DE EQUILIBRIO DEL CONTACTOR
USUALMENTE 2-5 gal/lb agua (ECONOMICO)
ES FUNCION DE :
dLbs
WWW
in
outin
![Page 14: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/14.jpg)
CAUDAL DE CIRCULACION DE TEG
1 ETAPA DE EQUILIBRIO 2 ETAPAS DE EQUILIBRIO
![Page 15: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/15.jpg)
2,5 ETAPAS DE EQUILIBRIO 3 ETAPAS DE EQUILIBRIO
CAUDAL DE CIRCULACION DE TEG
![Page 16: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/16.jpg)
CONCENTRACION DE GLICOL RICO
pobreglicolagua
gasretiradaagua
pobreglicolglicol
pobreglicolglicol
ricoglicol mmm
mwt
%
LAS UNIDADES EN LBS/D O LBS/MMPIE3/D
![Page 17: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/17.jpg)
30 MMPIE3/D ESTÁNDAR DE GAS DE 0,65 G.E. @ 600 PSIA Y 100 OF SERA DESHIDRATADO HASTA 7 LBS/MMPIE3. ESTIME LOS PARÁMETROS REQUERIDOS DE LA PLANTA DE GLICOL
DISEÑO DEL PROCESO
Concentración de glicol:
A 600 psia @ 100 oF, el gas saturado contiene 90 lbs/MMpie3
7 lbs/MM → 24 oF de punto de rocio @ 600 psia
Se supone 10 oF “Approach” → Punto de rocio : 14 oF
Se lee concentración de glicol @ 100 oF Tcontactor→ 98,8 % wt
![Page 18: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/18.jpg)
DISEÑO DEL PROCESO
TASA DE CIRCULACION
A 600 psia @ 100 oF, GAS → 90 lbs/MMpie3
922,090790
in
outin
WWW
CONVENIENTE LA MENOR TASA POSIBLE: 3 gal TEG/lb agua
Para dos (2) etapas de equilibrio
gpmdd
MMpieMMpielbs
lbgalgpm agua
agua
TEG 2,5min1440
13079033
3
min
72,12490330790 3
lbsdlbs
dMMpie
MMpielbsmretirada
![Page 19: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/19.jpg)
CONCENTRACIÓN GLICOL RICO
pobreglicolagua
gasretiradaagua
pobreglicolglicol
pobreglicolglicol
ricoglicol mmm
mwt
%
DISEÑO DEL PROCESO
gallbs
gallb
gallb
pobreglicol 32,928,8012,034,9988,0
min9,47988,032,9
min2,5 lbs
gallbsgalm
pobreglicolglicol
min58,0012,032,9
min2,5 lbs
gallbsgalm
pobreaguaglicol
%4,9510058,072,19,47
9,47%
ricoglicolwt
gallbs
gallb
gallb
ricoglicol 29,928,8046,034,9954,0
gpmlb
gallbslbslbsgpmricoglicol 40,5
29,91
min58,0
min72,1
min9,47
![Page 20: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/20.jpg)
DISEÑO DEL PROCESO
LC
LC
PC
30 MMPCND
100 oF
600 psi
90 lbs/MM
GLICOL POBRE
GLICOL RICO
ACUMULADOR
VAPOR DE AGUA
7 lbs/MM
115 oF
5,2 gpm
98,9 % TEG
400 oF, 15 psia
5,2 gpm
Max 150 oF 605 psia
5,4 gpm
100 oF
600 psia,
95,4% TEG
5,4 gpm
60 psia
![Page 21: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/21.jpg)
LOS EQUIPOS: EL CONTACTOR
LC
LC
![Page 22: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/22.jpg)
EL CONTACTOR: DIMENSIONES
L
D
6 pie
tr
EFICIENCIA DE ETAPAS (+/-):25 – 30% EN PLATOS
60 pulg (1.5 m) / ETAPA TEORICA (Relleno)
24 pulg V
VLMAX KV
DIAMETRO
![Page 23: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/23.jpg)
30 MMPIE3/D ESTÁNDAR DE GAS DE 0,65 G.E. @ 600 PSIA Y 100 OF SERA DESHIDRATADO HASTA 7 LBS/MMPIE3. ESTIME LOS PARÁMETROS REQUERIDOS DE LA PLANTA DE GLICOL. DIMENSIONE LA COLUMNA.
ALTURA
2 ETAPAS @ 25%→ 8 PLATOS @ 24”/plato→16 pie
RELLENO: 2 etapas x 60 pulg → 120 pulg → 10 pie
DIAMETROS
EL CONTACTOR: DIMENSIONES
spieKV
V
VLMAX 93,0
229,6916,0
spie
segd
lbspie
lbmollbs
stdpielbmol
dstdMMpieQgas
33
3
36
6,8864001
22965,0
5,37911030
![Page 24: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/24.jpg)
EL CONTACTOR: DIMENSIONES
lg484,34
24,92
2
max
pupieddpieVQ
A gas
SI CONSIDERAMOS RELLENO:
spieKV
V
VLMAX 74,1
229,6930,0
lg365,24
91,42
2
max
pupieddpieVQ
A gas
![Page 25: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/25.jpg)
EL CONTACTOR: PROBLEMAS
SGTSNTPK
28
ΔP Caída de presión a través de sección, psiNT Numero de platosTS Espaciamiento de platos, pulgSG Gravedad especifica prom. liquido desaireado
K0,18-0,25 Plato cerca de mejor eficiencia0,35-0,40 Arrastre y alta espuma
> 0,5 Inundación totalmente desarrollada0,10 – 0,12 Baja eficiencia debido a lloriqueo
0-0,10 No hay nivel de liquido, y los platos probablemente reposan en el fondo de la columna
LC
LC
![Page 26: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/26.jpg)
DIAMETRO DEL CONTACTOR CRITICO → BAJA CARGA DE LIQUIDO
ESPUMA AFECTA EL RENDIMIENTO Y EFICACIA
T GLICOL POBRE ↑ Y AROMATICOS ↑ ESPUMA
LOS PLATOS SE ENSUCIAN→FLOODING (INUNDACION)
EL CONTACTOR: PROBLEMAS
DOS TIPOS: ARRASTRE Y EVAPORACION
EVAPORACION ↓ SI Tgas < 120 oF. TIPICAMENTE 0,1 gal/MMpie3
ARRASTRE AFECTADO POR ESPUMA: INYECCION DE ANTIESPUMANTE
PERDIDAS DE GLICOL
![Page 27: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/27.jpg)
EL INTERCAMBIADOR DE CALOR
EFECTO IMPORTANTE EN LA CARGA REQUERIDA DEL REBOILER
EL ENFRIADOR DE GLICOL PUEDE NO SER NECESARIO EN UNIDADES PEQUEÑAS
Glicol pobre del reboiler: 400 oF
Glicol pobre al enfriador: max: 140-150 oF
Glicol rico de columna: Tgas
Glicol al trifásico y reboiler:
Approach Típico: 30-40 oF
![Page 28: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/28.jpg)
EL SEPARADOR TRIFASICO
LC
EL GLICOL ABSORBE 1 scf/gal glicol @ 1000 psia, 100 oF
Poper: 40-75 psia
3-5 MINUTOS PARA DEGASIFICACION
20-30 MINUTOS PARA REMOCION DE HIDROCARBUROS
PC
![Page 29: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/29.jpg)
EL REGENERADOR
COLUMNA RELLENO SIN REFLUJO
CALOR APROXIMADO
5,04lg glicolgpmpud
glicolgpmhrBtuQ
601500
hrlb
lbbtuLHV
hrbtuq
ma
fuel
![Page 30: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/30.jpg)
DENSIDAD CALORICA:
8000 Btu/hr-pie2 máximo
6000 Btu/hr-pie2 recomendado
10000 Btu/hr-pie2 quemador
2600 o
F2000 o
F
1400 o
F 1100 o
F
900 o
F
430 o
F420 o
F
410 o
F 406 o
F
EL REGENERADOR
2
2
pie
piehrbtuhrbtuq
Areaa
serpentin
Glicol
Tubo de fuego
![Page 31: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/31.jpg)
Gas Combustible
AGOTAMIENTO CON VAPOR
REDUCE PRESIÓN PARCIAL. INCREMENTA CONCENTRACIÓN
Gas Combustible
Solvente de despojamiento
Agua
DRIZO
SOLVENTE EN CIRCUITO CERRADO C5-C8: EXTRAE AROMÁTICOS.
99,99% CONCENTRACIÓN
EL REGENERADOR: OPCIONES DE REGENERACION
![Page 32: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/32.jpg)
Gas Combustible
Glicol rico
COLDFINGER
AL CONDENSAR VAPOR DE AGUA EN EL ACUMULADOR, SE REDUCE % AGUA EN VAPOR Y SE LIBERA AGUA DEL GLICOL POBRE, INCREMENTANDO % DE GLICOL
99,9% CONCENTRACIÓN
EL REGENERADOR: OPCIONES DE REGENERACION
GLICOL TEMPERATURA
EG 165 oC – 329 oF
DEG 164 oC – 328 oF
TEG 206 oC – 404 oF
TREG 238 oC – 460 oF
T DESCOMPOSICION
![Page 33: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/33.jpg)
EL REGENERADOR: OPCIONES DE REGENERACION
GAS STRIPPING
![Page 34: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/34.jpg)
Proceso Concentración TEG (% wt)
Depresión de Pto Rocío al Agua Posible (oF)
Vacío 99,2 – 99,9 100 - 150
Stripping Gas 99,2 – 99,97 100 - 150
COLDFINGERTM 99,9 100 - 150
DRIZOTM 99,99 + 180 - 220
EL REGENERADOR: OPCIONES DE REGENERACION
![Page 35: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/35.jpg)
LA BOMBA DE GLICOL
ALTERNATIVA
DOSIFICADORAS
CENTRIFUGA MULTIETAPA O ALTA VELOCIDAD O
![Page 36: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/36.jpg)
EQUILIBRIO: TEMPERATURA DEL REHERVIDOR (CONCENTRACIÓN), TEMPERATURA DEL ABSORBEDOR
CAPACIDAD: BOMBA DE GLICOL, VOLUMEN ACTUAL DE GAS, CONDICIÓN FÍSICA DEL ABSORBEDOR TAPONAMIENTO: PRESENCIA DE CONTAMINANTES
PROBLEMAS OPERACIONALES
LA MAYORIA DE LAS LIMITACIONES EN PLANTAS DE GLICOL SE ASOCIAN A:
![Page 37: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/37.jpg)
ESPUMA
DEGRADACION DEL GLICOL
TEMPERATURA DEL GLICOL A ABSORCION
TAPONAMIENTO CON SALES DE LA COLUMNA REGENERADORA
DISEÑO DE LA COLUMNA ABSORBEDORA
PERDIDA DEL GLICOL POR PICADURAS EN HX O SERPENTIN DEL REGENERADOR
PERDIDA DE GLICOL POR SELLOS
AROMATICOS
PROBLEMAS OPERACIONALES
![Page 38: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/38.jpg)
ESPUMA
ABSORCION DE AROMATICOS O COMPUESTOS DE AZUFRE
ARRASTRE DE LIQUIDOS
PRODUCTOS DE CORROSION
GENERADA POR:
CONSIDERAR:
DISTANCIA ENTRE PLATOS
INYECCION DE ANTIESPUMANTE → OJO CON SOBREDOSIFICACION Y PRODUCTO ADECUADO
![Page 39: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/39.jpg)
EXPOSICION DEL GLICOL AL OXIGENO
ALTA TEMPERATURA REGENERACION > 400 oF
Ph ↓ HIDRÓLISIS DE SALES
COMPUESTOS DE AZUFRE ABSORBIDOS EN GLICOL
GENERADA POR:
CONSIDERAR:
FILTRACION 100 %
INERTIZACION CON GAS EN TANQUES
INYECCION DE TRIETANOLAMINA
DEGRADACION
![Page 40: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/40.jpg)
PERDIDAS DE GLICOL
TEMPERATURA ALTA: TEMPERATURA BAJA:
ABSORCION DE PESADOS
TEMPERATURA AL ABSORBEDOR
CONSIDERAR:
ΔT glicol-gas = 15 oF
ALEJAR GAS DE PTO DE ROCIO
ADICIONAR AREA DE INTERCAMBIO DE CALOR
![Page 41: Deshidratacion Con Glicol](https://reader033.fdocuments.co/reader033/viewer/2022061121/546de403b4af9f717f8b4669/html5/thumbnails/41.jpg)
TAPONAMIENTO POR SALES
ARRASTRE DE FLUIDOS DE PRODUCCION CON SALES (NaCl)
GENERADA POR:
EFECTOS
TAPONAMIENTO DE PLATOS Y EMPAQUES, DEPOSITOS EN TUBOS DEL REHERVIDOR
Ph
CONSIDERAR:
MEJORAR SEPARACION AGUAS ARRIBA