DIMENSIONAMIENTO DE LÍNEAS (MPR-A-001-2002)
Transcript of DIMENSIONAMIENTO DE LÍNEAS (MPR-A-001-2002)
-
7/28/2019 DIMENSIONAMIENTO DE LNEAS (MPR-A-001-2002)
1/2
CLIENTE Rev.
PEMEX A
UBICACIN B
Sonda de Campeche, Mexico CPLATAFORMAAKAL-C
1.0 DATOSSOBREDISE O % = 20
FLUJO DE LQUIDO TOTAL Ql BPD 150,000.000
FLUJO DE LQUIDO TOTAL Ql gpm 4,375.005
GRAVEDAD ESPECIFICA Sl ADIMENSIONAL 0.956
CONSTANTE EMPIRICO C ADIMENSIONAL 100.000
Z ADIMENSIONAL 0.993
LONGITUD DE LA TUBERA L m 50.00
LONGITUD DE LA TUBERA L ft 164.04
FACTOR DE FRICCIN MOODY f ADIMENSIONAL 0.0180
1.1 FLUJO NORMALQ= 4 375.01 m
1.2 FLUJO M XIMOFLUJO NORMAL x SOBREDISE O
Q= 5 250.01 m
1.3 FLUJO M NIMOFLUJO RATED x 0 5
Q= 2 187.50 m
UNA FASE
FASE LQUIDA
CONSTANTES
FACTOR DE COMPRESIBILIDAD DEL
GAS
-
7/28/2019 DIMENSIONAMIENTO DE LNEAS (MPR-A-001-2002)
2/2
PARA FLUJO LAMINAR f =f = 64/NR