Intercambiador de Calor 2014B

5
Toma de datos: Flujo paralelo Termostato Teaire (T1) Tsaire (T4) Teagua Tsagua Vol (ml) t (seg)Tdtubo (T2) 150 31.3 29.6 20.1 23 100 28 26 230 43.5 32.6 20 24 100 29 31 330 53.1 34.9 20 25 100 27 34 380 65.4 37 20 26 100 27 38 Para el aire Para el agua DTML ha DTML hag 5.3 6.6 5.9263 70.6241 3 2.9 2.9497 60.0708 12.5 8.6 10.4287 53.4470 7 4 5.3608 44.0185 19.1 10.9 14.6187 51.1907 9 4 6.1658 51.3835 27.4 12 18.6523 48.1448 12 5 7.9957 47.5482 NUT 0.3263 0.6897 0.8749 1.0649 Toma de datos: Contraflujo Termostato Teaire (T1) Tsaire (T4) Teagua Tsagua Vol (ml) t (seg)Tdtubo (T2) 150 32.5 29.7 22 23 100 14 27 230 42.3 31.8 22 24 100 15 30 330 68.4 35.2 22 25 100 16 38 380 80.9 36.3 22 26 100 16 40 Para el aire Para el agua DTML ha DTML hag 5.5 6.7 6.0803 47.4725 4 1 2.1640 56.4690 12.3 8.8 10.4525 51.5479 6 1 2.7906 81.7434 30.4 12.2 19.9341 38.0100 13 1 4.6785 68.5651 40.9 13.3 24.5690 41.1193 14 1 4.9260 86.8259 DTa DTb DTa DTb DTa DTb DTa DTb 0.3263 0.6897 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 Flujo Paral NUT Efectividad

description

ing. termica

Transcript of Intercambiador de Calor 2014B

Page 1: Intercambiador de Calor 2014B

Toma de datos: Flujo paralelo

Termostato Teaire (T1) Tsaire (T4) Teagua Tsagua Vol (ml) t (seg) Tdtubo (T2) Titubo (T3)150 31.3 29.6 20.1 23 100 28 26 23230 43.5 32.6 20 24 100 29 31 24330 53.1 34.9 20 25 100 27 34 24380 65.4 37 20 26 100 27 38 25

Para el aire Para el aguaDTML ha DTML hag

5.3 6.6 5.9263 70.6241 3 2.9 2.9497 60.070812.5 8.6 10.4287 53.4470 7 4 5.3608 44.018519.1 10.9 14.6187 51.1907 9 4 6.1658 51.383527.4 12 18.6523 48.1448 12 5 7.9957 47.5482

NUT0.32630.68970.87491.0649

Toma de datos: Contraflujo

Termostato Teaire (T1) Tsaire (T4) Teagua Tsagua Vol (ml) t (seg) Tdtubo (T2) Titubo (T3)150 32.5 29.7 22 23 100 14 27 23230 42.3 31.8 22 24 100 15 30 23330 68.4 35.2 22 25 100 16 38 23380 80.9 36.3 22 26 100 16 40 23

Para el aire Para el aguaDTML ha DTML hag

5.5 6.7 6.0803 47.4725 4 1 2.1640 56.469012.3 8.8 10.4525 51.5479 6 1 2.7906 81.743430.4 12.2 19.9341 38.0100 13 1 4.6785 68.565140.9 13.3 24.5690 41.1193 14 1 4.9260 86.8259

DTa DTb DTa DTb

DTa DTb DTa DTb

0.3263 0.6897 0.8749 1.06490.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

Flujo Paralelo

NUT

Efec

tivid

ad

Page 2: Intercambiador de Calor 2014B

NUT0.33930.79211.34791.5108

0.3393 0.7921 1.3479 1.51080.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

Contraflujo

NUT

Efec

tivid

ad

Page 3: Intercambiador de Calor 2014B

A1 A2 Tbaire Tbagua m'(agua) q m'(aire)0.1033 0.244 30.45 21.55 0.00357 43.23484 0.025260.1033 0.244 38.05 22.00 0.00344 57.57791 0.005250.1033 0.244 44.00 22.50 0.00370 77.30367 0.004220.1033 0.244 51.20 23.00 0.00370 92.76440 0.00324

Coeficiente global EfectividadR1-2 Rk Rc U Cagua Caire E (%)

0.13707 0.00024 0.06823 19.93970 14.9086 25.4323 25.890.18112 0.00024 0.09311 14.93188 14.3945 5.2824 46.380.18911 0.00024 0.07976 15.22939 15.4607 4.2475 54.980.20107 0.00024 0.08619 14.25485 15.4607 3.2664 62.56

A1 A2 Tbaire Tbagua m'(agua) q m'(aire)0.1033 0.244 31.10 22.50 0.00713 29.81713 0.010570.1033 0.244 37.05 23.00 0.00665 55.65864 0.005260.1033 0.244 51.80 23.50 0.00624 78.26997 0.002340.1033 0.244 58.60 24.00 0.00624 104.35996 0.00232

Coeficiente global EfectividadR1-2 Rk Rc U Cagua Caire E (%)

0.20392 0.00024 0.07258 14.80958 29.8171 10.6490 26.670.18780 0.00024 0.05014 17.20737 27.8293 5.3008 51.720.25468 0.00024 0.05977 13.02313 26.0900 2.3575 71.550.23543 0.00024 0.04720 14.48856 26.0900 2.3399 75.72

0.3263 0.6897 0.8749 1.06490.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

Flujo Paralelo

NUT

Efec

tivid

ad

Page 4: Intercambiador de Calor 2014B

0.3393 0.7921 1.3479 1.51080.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

Contraflujo

NUT

Efec

tivid

ad