Anderson Instrument Company8/15/2013
AndersonInstrument Company, Inc.
Medicin de Turbidez
Alex Araujo
Gte. Regional
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
2/34
Anderson Instrument Company8/15/2013
Turbidez: ?Que es?
Normas Internaciones de medicin de turbidez
Unidades de medicin
Tcnicas analticas de medicin
Diseo de equipo bajo la norma ISO 7027
Propiedades y caractersticas que influyen la medicin
Calibracin de instrumentos
Especificaciones y funcionamiento de turbidmetros Anderson
Resume de Capacitacin
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
3/34
Anderson Instrument Company8/15/2013
Turbid ez -Qu es?
.
La turbidez es una caracterstica ptica o propiedad de un lquido, queen trminos generales describe la claridad u opacidad del lquido.
La turbidez no tiene que ver con el color, sino que se relaciona mscon la prdida de transparencia debida al efecto de partculas en
suspensin, material coloidal, o ambos. Una falta de turbidez resultaen la pureza ya que es, en parte, el efecto de estos diversos materialesen suspensin sobre la luz que atraviesa el lquido.
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
4/34
Anderson Instrument Company8/15/2013
Visible light
wavelength
radiatedpower
La longitud de onda de la radiacin visible: 400...700 nm.
Influencia del color
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
5/34
Anderson Instrument Company8/15/2013
Agua de Llave Leche Descremada Cola
Comparacin de Turbidez
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
6/34
Anderson Instrument Company8/15/2013
Existen diferentes normas vigentes con los lineamientos para ladeterminacin de turbidez en la calidad del agua, tanto internacionales
como nacionales :ISO 7027. (1999). Water quality - Determination of turbidity.
DIN 38404-10. (1995). German standard methods for the examination of water,
waste water and sludge.ASTM D1889-00. Standard test method forturbidity of water.
Method 180.1 USEPA: Determination of turbidity by nephelometry.
NMX-AA-038-SCFI-2001:Anlisis de agua - determinacin de turbiedad enaguas naturales, residuales y residuales tratadas.
NOM-127-SSA1-1994: Salud ambiental, agua para uso y consumohumano. Lmites permisibles de calidad y tratamiento a que debe
someterse el agua para su potabilizacin.
NORMAS
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
7/34
Anderson Instrument Company8/15/2013
Units of Measure of Turbidity:
NTU - Nephelometric Turbidity Units (only 90 degree scattered light
method)
EBC European Brewing Convention (equivalent to TE/F)
FTU Formazine Turbidity Units (Scattered light method)
FNU Formazine Nephelometric Units (independent of
measurement angle)
Unidades de medicin
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
8/34
Anderson Instrument Company8/15/2013
La unidad nefelomtrica de turbidez, (UNT) expresada habitualmentecon el acrnimo NTU del inglsNefelometric Turbidity Unit, es una
unidad utilizada para medir la turbidez de un fluido.
Corresponde con una concentracin del producto utilizado como patrn
llamado Formacina, que es una solucin que se puede crear utilizando
Sulfato de Hidracina y Hexametilentetraamina en unas proporciones
conocidas para formar el patrn de turbidez .
Suspensin Patrn de Formacina: Se prepara de la siguiente forma: a)
Solucin 1: disolver 1 g de sulfato de hidracina ( MUY PELIGROSO )
en agua destilada y dilyase hasta 100 ml.
El instrumento usado para su medida es el nefelmetro o turbidmetro,
que mide la intensidad de la luz dispersada a 90 grados cuando un rayo
de luz pasa a travs de una muestra de agua.
Patrn Formacina. Qu es?
http://es.wikipedia.org/wiki/Turbidezhttp://www.venturemeasurement.com/http://es.wikipedia.org/wiki/Nefel%C3%B3metrohttp://es.wikipedia.org/wiki/Nefel%C3%B3metrohttp://es.wikipedia.org/wiki/Turbidezhttp://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
9/34
Anderson Instrument Company8/15/2013
Unidades de medicin ISO 7027
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
10/34
Anderson Instrument Company8/15/2013
Tcnica Analtica de Medicin
Nefelometra: Tcnica analtica basada en la dispersin de la luz por partculas
en suspensin en el seno de una disolucin, midiendo el haz de luz en la
direccin que forma un ngulo recto (90).
Turbidimetra: Tcnica analtica basada en la dispersin de la luz por
partculas en suspensin en el seno de una disolucin, la cual mide la
disminucin de la transmitancia del haz de luz al atravesar la muestra.
Big particles: > 0,1 m
Small particles: < 0,1 m
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
11/34
Anderson Instrument Company8/15/2013
The 90 signal is almost completey independent to the particlesize or color and is mostly affected by particle quantity.
The forward scattered light (11...25) is mostly affected by theparticle size and quantity.
TAMAO Y CANTIDAD DE PARTCULASANGULO DE MEDICIN
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
12/34
Anderson Instrument Company8/15/2013
Los instrumentos actual y comnmente utilizados son los turbidmetros,
que emplean un mtodo cuantitativo y deben cumplir los siguientescriterios en el diseo ptico:
La longitud de onda de la radiacin incidente debe ser de 860 nm. La fuente de
luz puede ser lmpara de tungsteno; diodos (leds) lser.
El ancho de banda espectral debe ser menor o igual a 60 nm. La convergencia de
la radiacin incidente no debe exceder 1,5 en turbidmetros de radiacin difusa
y u o 2,5 en turbidmetros de radiacin atenuada.
El ngulo de medicin entre la radiacin incidente y la radiacin difusa debe ser
de 90 2,5 en turbidmetros de radiacin difusa y u o 0 2,5 en turbidmetrosde radiacin atenuada.
La distancia recorrida por la luz incidente y dispersada dentro del tubo de
muestra, no debe exceder 10 cm.
DISENO DE EQUIPO: NORMA ISO 7027
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
13/34
Anderson Instrument Company8/15/2013
Cantidad de partculas
Tamao de las partculas
Longitud de onda de luz utilizada
Geometra de las partculas
Indic de refraccin de las partculas
Presencia de burbujas de aire
PROPIEDADES DEL PRODUCTO QUEAFECTAN LA MEDICIN DE TURBIDEZ
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
14/34
Anderson Instrument Company8/15/2013
All scattered light measurements are calibrated acc. to the Formazinestandard.
This standard was established in 1926. Instruments must becalibrated to Formazine standards and produce repeatable values.
Precondition: They must be calibrated utilizing the formazinestandard!
Calibration of scattered light measurements
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
15/34
Anderson Instrument Company8/15/2013
Anderson Turbidity Products
ITM-3Backscatter (reflection)
>2000 NTU
ITM-490 scattered light
0
5000 NTU
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
16/34
Anderson Instrument Company8/15/2013
Anderson ITM-3
Backscatter Turb id i ty Mon i tor
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
17/34
Anderson Instrument Company
ITM-3 Turbidity Monitor
8/15/2013
Suitable for high turbidities
Media with a turbidity of at least
2000 NTU (ca. 6 %)
Product phase separation (e.g.
skimmed milk
milk)
Yeast harvest (process automation
in breweries)
Phase separation in cleaning
process
Functional principles: Backscatter (reflection) principle
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
18/34
Anderson Instrument Company8/15/2013
Sender Empfnger
Lichtwellenleiter
MediumPartikel
Functional principles: Backscatter (reflection) principle
ITM-3
Infra-red LED emits light intomedia through the sapphire
lens
Receiver measures amount
of light reflected back by
particles suspended in the
media
Generates signal that is
proportional to the amount
of particles = relative
turbidity
Transmitter
IR-LED
Receiver
photo diode
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
19/34
Anderson Instrument Company8/15/2013
ITM-3 Techn ical Featu res
-Measuring range starts at 2000 NTU
-Display for indication and programming
-4-20mA output assignable to 5 ranges
(10,20,50,100,200)
-DC Switched output adjustable 0- 200-Adjustable dampening 0,1,3,6,13, and 25sec
-One unit with transmitting beam, and
receiver-no need for any other parts
- 2 M12 connectors(1 needed for power withanalog output)
- 3-A
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
20/34
Anderson Instrument Company8/15/2013
ITM-3 Piping Ins tal lat ion
Pipe must be filled! Air bubbles adulterate measurement
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
21/34
Anderson Instrument Company8/15/2013
Analyt ical Ins trum entat ion
Product-to-water transitions
Water-to-product transitions
Product-to-product transitions
CIP Rinse monitoring
Effluent Monitoring
Filter Monitoring
Yeast harvest control
Applications
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
22/34
Anderson Instrument Company8/15/2013
Analyt ical Ins trum entat ion
ITM-3L ITM-3AViscous Products
Ice cream mix
yogurt
Low velocity flow
All other applications
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
23/34
Anderson Instrument Company8/15/2013September 2010 Sales Workshop
ITM-3 Specif ic ation s
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
24/34
Anderson Instrument Company8/15/2013
Analyt ical Ins trum entat ion
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
25/34
Anderson Instrument Company8/15/2013
Anderson ITM-4
4 Beam Turbid i ty Meter
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
26/34
Anderson Instrument Company8/15/2013
ITM-4 How Does it Work?
4-beam alternating light
Emitter 1 activeReceiver 1 is measuring transmission light
Receiver 2 is measuring scattering light
Emitter 2 activeReceiver1 is measuring scattering lightReceiver 2 is measuring transmission light
5 x Repetition = 20 Values
Measurement angle for
transmission light according
to ISO 7027: 90
Anderson ITM-4
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
27/34
Anderson Instrument Company8/15/2013
wave length 860 nm (colorindependent)
4 ranges selectable via display orvia digital input
switchable between NTU and EBC
Output 420 mA
Switch output 24 V / 50 mA max.
High repeatability < 1 % of f.s.
Optics: sapphire or quartz
ITM-4 Technical Features
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
28/34
Anderson Instrument Company8/15/2013
ITM-4 Piping Ins tal lat ion
Pipe must be filled! Bubbles and air adulterate measurement
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
29/34
Anderson Instrument Company8/15/2013
Analyt ical Ins trum entat ion
11 preset ranges, any 4 can be assigned for remote selection via 24Vdc
Decoupled input
4-20 mA output (4-wire)
1 24VDC switched output, referenced to ground of power supply
On-board, backlit LCD display, 2 lines x 8 digits
2 M12 connectors, 1 for power and output, 1 for switching and remote
range selection
3A Compliant
Alternating beam method compensates for fouling of lens
860 nm wavelength (color independent)LED light source provides longer life and less expensive replacement cost
Must allow 5X the pipe diameter of straight pipe (upstream) and 2X
(downstream)
Specifications of the ITM-4
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
30/34
Anderson Instrument Company8/15/2013
-Product standardization and quality control oflow turb id i tymedia-Control of separator speed based on solids starting to appear in
discharge stream
-Filter monitoring where solids starting to appear in downstream fluid
indicates a failed filter
-Waste water control
-Yeast dosing in a brewery
-Bottled water for QC
-COW (Condensate of whey) water
Chill media monitoring
ITM-4 App l icat ions
2011 Distributor Sales Workshop
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
31/34
Anderson Instrument Company8/15/2013
Analyt ical Ins trum entat ion
ITM-4-Cost of ownership
- LEDs longer life and less expensive versus tungten lamps
-Non color dependent
- ITM-4 features LED wave length
-On board display and transmitter
- Lower install cost over remote panel units.
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
32/34
Anderson Instrument Company8/15/2013
ITM-4 Specif ic ation s
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
33/34
Anderson Instrument Company8/15/2013
Analyt ical Ins trum entat ion
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/ -
7/27/2019 ITM Spanish Presentation 10-13-2011
34/34
Anderson Instrument Company
Questions ?
Analyt ical Ins trum entat ion
http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/http://www.venturemeasurement.com/