MURO_01PRESA O MURO DE CONTENCIONPROYECTO:EXPEDIENTE:DATOS(MTS)B=1.20T=0.20h=1.30H=1.10E=0.25G=0.25D=2.30F=1.10M=0.25N=0.25*H es la altura del suelo o fluidoPeso especifico del concreto,=(w)2.40T/m3Peso especifico suelo o Agua=(&)=1.00T/m3Angulo de Friccion ()=34.00Presion admisible de terreno=(q adm)2.00Kg/cm2Coeficiente Friccion (f)0.40PPESOS (Ton)Brazo Giro(m)P*XP10.330.420.14P21.100.600.66P30.660.830.54P43.740.602.25P50.600.950.57P60.660.870.57P70.281.080.30TOTAL7.375.335.03NMrArea de la Seccin=2.43m2Ka=tg2(45-O/2)=0.283Ha=1/2Ka*&*Hp^2=0.814Ma=0.65T-mVERIFICACION AL DESLIZAMIENTO Y AL VOLTEOFSD=Hr/Ha=f*N/Ha=3.622>1,5CONFORMEFSV=Mr/Ma=7.720>1,75CONFORMEVERIFICACION DE PRESIONES EN EL TERRENOXo=(Mr-Ma)/P=0.59me=B/2-Xo0.01mB/6=0.20mSe cumple?0.011.50D2.000.790.710.50f =0.40E0.25F.S.V.=5.39>2.00F0.25Angulo del terreno =0.00 =0.00G0.35Ang. de friccin interna =45.00FiFi =45.00Presin admisible terreno=1.00Kg/cm2Coef. de friccin Terreno =0.40fArea de la Seccin=1.76m2VERIFICACION AL DESLIZAMIENTO Y AL VOLTEOF.S.D. =3.24>1.50OK!F.S.V. =5.39>2.00OK!VERIFICACION DE PRESIONES EN EL TERRENOXo=(Mr-Ma)/P=0.49me=B/2-Xo=0.09mB/6=0.19mSe cumple?0.09