Presentación diagnósticos Energéticos de Éxito

23
DIAGNOSTICO ENERGÉTICO DE SEGUNDO NIVEL PROGRAMA DE AHORRO DE ENERGÍA Cel.: (999)1783326 Tel.: (999)2861427 Correo Electrónico: [email protected] C. 29ª No. 435 x 28 y 30. Poligono 108. Mérida, Yucatán ASESORÍA E IMPLEMENTACIÓN DE PROYECTOS DE AHORRO DE ENERGÍA CALIDAD Y AHORRO DE ENERGÍA ING. ALEJANDRO VIVAS RIVEROL

description

I have the opportunity to help this Companies in thier energy Saving requirements

Transcript of Presentación diagnósticos Energéticos de Éxito

  • 1. Cel.: (999)1783326 Tel.: (999)2861427 Correo Electrnico: [email protected] C. 29 No. 435 x 28 y 30. Poligono 108. Mrida, Yucatn CALIDAD Y AHORRO DE ENERGA ING. ALEJANDRO VIVAS RIVEROL

2. CASOS DE XITO 3. AIRTEMP SA DE CV DIAGNSTICO ENERGTICO DE XITO DIAGNSTICO 2 NIVEL INYECTORAS HORNOS COMPRESORES MOTORES MQUINAS EN GENERAL BALANCE DE ENERGA CONTROL DE LA DEMANDA FACTOR DE POTENCIA 4. BALANCE DE ENERGA AIRTEMP SA DE CV CARGAS KW % HRAS AL MES KWH % $ TOTALES (INCLUYE IVA) % 1.- INYECTORAS Y ESTRACTORES 232.03 28% 396 91,883.30 30.35% 152,444.78$ 29.85% 2.- HORNOS Y MOTORES PERIFERICOS 232.94 28% 398 92,711.51 30.62% 153,666.39$ 30.09% 3.- REA HERRAMENTALES N2 65.73 8% 184 12,093.89 3.99% 24,625.79$ 4.82% 4.- COMPRESOR 75HP, TORRE DE ENFRIAMIENTO Y SECADORES 76.93 9% 397 30,542.95 10.09% 50,649.02$ 9.92% 5.- CHILLER Y BOMBAS 48.62 6% 397 19,302.14 6.37% 32,008.52$ 6.27% 6.- CABINAS DE PRUEBAS DE FUGAS 5.96 1% 207 1,232.69 0.41% 2,413.54$ 0.47% 7.- A.A. DE LA PLANTA 34.07 4% 184 6,268.88 2.07% 12,764.80$ 2.50% 8.- ILUMINACIN DE LA PLANTA 132.50 16% 368 48,760.00 16.10% 82,112.62$ 16.08% TOTAL 829 100% 302,795.36 100% 510,685.45$ 100% TARIFA HM (N1 Y N2) 5. CORRECCIN DE F.P. AIRTEMP SA DE CV 505.76 56.940.00 100.00 200.00 300.00 400.00 500.00 600.00 01 09 05 02 10 06 03 11 07 04 12 08 05 01 09 06 02 10 07 03 11 kVAr Hrs KVAr 3f Actuales 0.97 0.58 0.00 0.20 0.40 0.60 0.80 1.00 1.20 01: 07: 02: 09: 03: 10: 05: 11: 06: 01: 07: 02: 09: 03: 10: 05: 11: 06: 01: 07: 02: 09: 03: 10: 05: 11: %F.P. Hrs FP 3f Actuales 373.3 3 0.00 50.00 100.00 150.00 200.00 250.00 300.00 350.00 400.00 01:10:00PM 09:40:00PM 06:10:00AM 02:40:00PM 11:10:00PM 07:40:00AM 04:10:00PM 12:40:00AM 09:10:00AM 05:40:00PM 02:10:00AM 10:40:00AM 07:10:00PM 03:40:00AM 12:10:00PM 08:40:00PM 05:10:00AM 01:40:00PM 10:10:00PM 06:40:00AM 03:10:00PM kVAr Hrs kVAr Nuevos Inductivos 3f (Banco Automtico de 157.5 kVAr de 15X10.5) 0.00 0.20 0.40 0.60 0.80 1.00 1.20 01:10:00 09:30:00 05:50:00 02:10:00 10:30:00 06:50:00 03:10:00 11:30:00 07:50:00 04:10:00 12:30:00 08:50:00 05:10:00 01:30:00 09:50:00 06:10:00 02:30:00 10:50:00 07:10:00 03:30:00 11:50:00 %F.P. Hrs F.P. Nuevo Instantneo 3f (Banco Automtico 157.5 kVAr automaticos de 15X 0.5) CONDICIONES PREVIAS: CONDICIONES SIMULADAS: 6. CORRECCIN DE F.P. (ANLISIS DE ARMNICAS) AIRTEMP SA DE CV 0.000 5.000 10.00 15.00 20.00 % 01:10:00.000 p.m. 26/09/2007 03:15:00.000 p.m. 03/10/2007 1 Days/Div 7:02:05:00 (D:H:M :S) 0.000 5.000 10.00 15.00 20.00 % 01:10:00.000 p.m. 26/09/2007 03:15:00.000 p.m. 03/10/2007 1 Days/Div 7:02:05:00 (D:H:M :S) 0.000 1.000 2.000 3.000 4.000 5.000 % 01:10:00.000 p.m. 26/09/2007 03:15:00.000 p.m. 03/10/2007 1 Days/Div 7:02:05:00 (D:H:M :S) 0.000 1.000 2.000 3.000 4.000 5.000 % 01:10:00.000 p.m. 26/09/2007 03:15:00.000 p.m. 03/10/2007 1 Days/Div 7:02:05:00 (D:H:M :S) ARMNICOS DE CORRIENTE ARMNICOS DE VOLTAJE 7. CORRECCIN DE F.P. (LMITES DE BANCOS DE CAPACITORES) AIRTEMP SA DE CVDATOS DEL BANCO DE CAPACITORES Datos kVAr nominales: 157.5kVAr Voltaje Nominal: 480.0V(3f) Voltaje de Operacin: 440.0V(3f) Compensacin Alimentada: kVAr Corriente Fundamental nominal: 225.45A Freceuncia Nominal: 60.0Hz Reactancia del capacitor: 1,229.2W DISTORSIN ARMNICAD DEL BUS DE VOLTAJE Volt. Volt. Corriente de Corriente de Armnico Frecuencia 0 mag., Vh lnea, Ih lnea, Ih no. (Hz) (% de fund.) (V) (% de fund.) (A) 1 60 100.00 254.03 100.00 225.45 2 120 0.00 0.00 3.47 7.81 3 180 1.00 2.54 17.51 39.488 4 240 0.00 0.00 0.92 2.0748 5 300 5.67 14.40 19.14 43.152 7 420 1.78 4.52 7.26 16.3605 9 540 0.33 0.85 3.07 6.9136 11 660 0.78 1.98 3.42 7.7196 13 780 0.44 1.12 3.42 7.7004 17 1020 0.11 0.28 2.69 6.0654 19 1140 0.21 0.54 2.08 4.6869 21 1260 0.22 0.57 1.83 4.1355 23 1380 0.33 0.83 2.32 5.2383 25 1500 0.44 1.11 2.81 6.3411 Distorsin de Voltaje (THD): 6.13% Voltaje rms del Capacitor: 254.51V Corriente de distorsin del capacitor: 28.28% Corriente rms del Capacitor: 234.29A LMITES DEL BANCO DE CAPACITORES CALCULADO (%) LMITE (%) SE EXCEDE EL LMITE Voltaje Pico: 102.0% 120.0% NO Voltaje Pico: Voltaje rms: 91.8% 110.0% NO Voltaje rms: Corriente rms: 103.9% 180.0% NO Corriente rms: kVAr: 113.6% 135.0% NO kVAr: 8. ANLISIS INYECTORAS AIRTEMP SA DE CV CINCINNATI MILACRON CINCINNATI MILACRON CINCINNATI MILACRON VAN DORN 350 TON REED 200TG TON#2 REED 200TG TON#1 LIEN YU D155 TON LIEN YU D355 TON LIEN YU D555 TON 3.934 7.640 1.636 7.083 30.860 11.418 7.129 1.231 0.721 $4.556 $8.847 $1.895 $8.202 $35.739 $13.224 $8.256 $1.426 $0.835 KWH/KG PLASTICO $/KG PLASTICO INDICES ENERGTICOS COSTO - $/kg Plastico Inyectrado REAL ($/kg) KWH/KG PLASTICO INYECTADO (REAL) $- $5,000.00 $10,000.00 $15,000.00 $20,000.00 CINCINNATI 1000 TON LIEN YU D555 TON $14,693.1 7 $2,692.66 $4,825.38 $3,215.62 $ / KWH - MES INYECTORA KWH/K G KG DE PLAST COSTO $ / KG DIFERENC IA DE COSTOS CINCINNATI 1000 TON 3.93 0.696 $ 4.56 $ 3.72 LIEN YU D555 O.72 0.696 $ 0.84 9. ANLISIS INYECTORAS AIRTEMP SA DE CV $- $5,000.00 $10,000.00 $15,000.00 $20,000.00 $25,000.00 $30,000.00 $35,000.00 $40,000.00 CINCINNATI1000TON LIENYUD555TON CINCINNATI700TON CINCINNATI500TON VANDORN350TON LIENYUD355TON REED200TG#2 LIENYUD155TON REED200TG#1 $14,693.17 $2,692.66 $28,379.74 $6,077.61 $8,867.34 $1,541.10$8,229.09 $1,901.01 $3,044.84 $4,825.38 $3,215.62 $8,183.58 $3,616.12 $2,688.11 $2,059.50 $2,211.15 $823.02 $1,662.90 RESUMEN AHORROS COMPARATIVOS ENTRE INYECTORAS $ / KWH - MES $ / KW - MES $- $5,000.00 $10,000.00 $15,000.00 $20,000.00 $25,000.00 $30,000.00 $35,000.00 $13,800.59 $25,647.45 $8,425.18 $7,277.29 $1,315.40 $1,851.22 $5,252.57 $722.90 $1,596.34 $965.85 AHORRO EN $/KWH -Mes) AHORRO EN $/KW 10. ANLISIS INYECTORAS AIRTEMP SA DE CV SUSTITUCIN RECOMENDADA AHORRO TOTAL AL MES ($) AHORRO TOTAL ANUAL ($) Cincinnati 1000 x Lien Yu D555 $15,651.80 $187,821.66 Cincinnati 700 x Cincinnati 500 $30,900.02 $370,800.27 Van Dorn 350 x Lien Yu D355 $9,148.08 $109,776.93 Reed 200 TG #2 x Lien Yu D155 $8,873.63 $106,483.58 Reed 200 TG #1 x Lien Yu D155 $2,281.26 $27,375.10 TOTAL $66,854.79 $802,257.53 11. FACTURACIN ANTERIOR AIRTEMP SA DE CV 12. FACTURACIN ACTUAL AIRTEMP SA DE CV 13. PCC AIRFOILS SA DE CV DIAGNSTICO ENERGTICO DE XITO DIAGNSTICO ENERGTICO DE 2 NIVEL HORNOS COMPRESORES AIRES ACONDICIONADOS MOTORES ILMINACIN EXTERNA CONTROL DE LA DEMANDA 14. BALANCE DE ENERGA PCC AIRFOILS SA DE CV SISTEMA DEMANDA CONSUMO COSTO % kW % kWH kW kWhbase kWhinter kWhpunta kWhtotal $/mes 1.- HORNOS 373.85 46,256.37 112,336.90 0.00 158,593.28 $ 227,204.25 38% 40% 2.- COMPRESORES 305.67 18,198.98 99,844.75 20,329.99 138,373.72 $ 194,885.84 31% 35% 3.- AIRE ACONDICIONADO 218.46 13,939.23 32,506.29 9,311.41 55,756.93 $ 81,818.48 22% 14% 4.- MOTORES y BOMBAS 69.55 9,553.75 22,279.34 6,381.90 38,214.99 $ 44,690.32 7% 10% 5.- ILUMINACIN 11.30 1,324.79 3,091.18 883.19 5,299.16 $ 6,432.11 1% 1% TOTAL 978.82 89,273.13 270,058.47 36,906.49 396,238.09 $ 555,031.00 100% 100% 15. ANLISIS HORNOS PCC AIRFOILS SA DE CV HORNOS (MPROG3) KWH/PROGRAMA $ KWH /PROGRAMA $ KW/PROGRAMA $ TOTAL - PROG HORNO A 367.14 $334.47 $18,056.23 $18,419.37 HORNO B 318.15 $289.7 $16,696.12 $16,985.83 HORNO C 313.2 $285.4 $15,311.04 $15,596.46 HORNO A HORNO B HORNO C $18,056.23 $16,696.12 $15,311.04 $334.467 $289.712 $285.410 COMPARACIN ENTRE HORNOS MEDICIONES DEL MPROG 3 MPROG3. $KWH MPROG3. $KW 16. ANLISIS HORNOS PCC AIRFOILS SA DE CV EXPLICACIN ANLISIS HORNOS. DIAPOSITIVA ANTERIOR La determinacin de dicha eficiencia no solo fue debida a la cantidad de amperes o potencia que consuma cada mquina, sino que hubo que homogeneizar criterios para que las distintas variables que condicionaban el consumo y demanda de los hornos sean comparables. Dichas variables tomadas en cuanta fueron: .-Programa Utilizado (duracin, rampa, demanda mx) .-Tipo de contenedor .-% de llenado del contenedor .-Tipo de producto .- Entre otros Una vez homogeneizado el criterio de comparacin, se determin la mquina mas eficiente. En este caso el horno C, con respecto de los otros hornos. 17. ANLISIS DE AIRE ACONDICIONADO PCC AIRFOILS SA DE CVC Total de la construccin: Manpostera Aluminio Total Carga trmica total: Qtot = 926,738.29 25,738.96 952,477.24 Btu/hr T.R. = 77.228 2.145 79.373 TR Total de la construccin: Manpostera Aluminio Total Carga trmica total: Qtot = 1,880,964.36 219,064.58 2,100,028.94 Btu/hr T.R. = 156.747 18.255 175.002 TR REQUERIMIENTO DE ACONDICIONAMIENTO DE AIRE PCC AIRFOILS SA DE CV. SIN AISLANTE TRMICO REQUERIMIENTO DE ACONDICIONAMIENTO DE AIRE PCC AIRFOILS SA DE CV. CON AISLANTE TRMICO 18. ANLISIS DE AIRE ACONDICIONADO PCC AIRFOILS SA DE CVC 0.00 50.00 100.00 150.00 200.00 250.00 ENE FEB MAR ABR MAY JUN JUL AGO SEPT OCT NOV DIC KW MESES DEMANDAS ANUALES DEMANDA FACTURABLE ANUAL CON EQ. ACTUALES CONSUMOS ANUALES APAGANDO 100TON CONSUMOS ANUALES SIST PROPUESTO 0.00 20,000.00 40,000.00 60,000.00 80,000.00 100,000.00 120,000.00 ENE FEB MAR ABR MAY JUN JUL AGO SEPT OCT NOV DIC KWH MESES CONSUMOS ANUALES CONSUMOS ANUALES CON EQ ACTUAL CONSUMOS ANUALES APAGANDO 100TON CONSUMOS ANUALES SIST PROPUESTO 19. ANLISIS AIRES ACONDICIONADOS PCC AIRFOILS SA DE CV EXPLICACIN SISTEMAS DE ACONDICIONAMIENTO DE AIRE EN PCC AIRFOIL SA DE CV, SE TENIAN 200 TONELADAS DE REFRIGERACIN PARA ACONDICIONAR LA NAVE INDUSTRIAL. ESTA CARGA ESTABA DIVIDIDA EN 8 UNIDADES DE PAQUETE DE 25 TON DE REF CADA UNA. AL APLICAR LA NOM 008 PARA EFICIENCIA EN EDIFICACIONES, VIMOS QUE PCC AIRFOILS CUMPLIA CON LA NORMA PARA EDIFICIOS EFICIEENTES Y ESTABA POR DEBAJO DE ELLA EN 9%, ADEMS, NOS DIMOS CUENTA QUE HACIENDO UN CLCULO DE LAS TONELADAS DE REFRIGERACIN QUE NECESITABA LA NAVE TOMANDO EN CUENTA EL RECUBRIMIENTO DE AISLANTE TRMICO CON ELQUE CUENTA, NO ERAN NECESARIAS LAS 200 TON, SINO SOLO 80 TON. SIENDO STE EL REQUERIMIENTO EN TONELADAS DE REFRIGERACIN DEL PERIDO MS CRTICO DEL AO. DICHO RESUMEN DE CLCULO SE MUESTRA EN LA LMINA ANTERIOR. CON ESTO SE DETERMIN APAGAR 100 TON DE REFRIGERACIN PRACTICAMENTE PERMANENTE MENTE EN TODO EL AO , CON LO QUE SE OBTIENEN AHORROS CUANTIOSOS. TAMBIN SE DETERMIN QUE EN EL HORARIO PUNTA EN EL PERODO DE INVIERNO, NO ES NECESARIO LA UTILIZACIN DE NINGUNO DE LOS PAQUETES PUES LAS TEMPERATURAS DE CONFORT SOLICITADAS POR PCC AIRFOILS SA DE CV, SE MANTIENEN EN ESE PERIODO. POR LTIMO, SE REGISTRARON AHORROS AL DIFERENCIAR LAS TEMPARATURAS DE USO DE LOS PAQUETES SEGN LOS REQUERIMIENTOS DE LOS PROCESOS. 20. ANLISIS CONTROL DE LA DEMANDA PCC AIRFOILS SA DE CV 0 100 200 300 400 500 600 700 800 00:30 02:00 03:30 05:00 06:30 08:00 09:30 11:00 12:30 14:00 15:30 17:00 18:30 20:00 21:30 23:00 kW Horas Demanda Pcc Airfoils Error de uso de maquinas en horario punta Base Intermedio Punta 0 100 200 300 400 500 600 700 800 900 1000 00:30 02:00 03:30 05:00 06:30 08:00 09:30 11:00 12:30 14:00 15:30 17:00 18:30 20:00 21:30 23:00 kW Horas Demanda Pcc Airfoils Uso correcto promedio de la demanda en el presente mes Base Intermedio Punta 21. ANISIS CNTROL DE DEMANDA PCC AIRFOILS SA DE CV EXPLICACIN DEL CONTROL DE DEMANDA EN LAS GRFICAS ANTERIORES SE PUEDE VER EL ANTES Y DESPUS DE LO REALIZADO EN PCC AIRFOILS SA DE CV EN CUANTO A CONTROL DE LA DEMANDA. LAS GRFICAS MUESTRAN LA DEMANDA HORARIA DURANTE UN DA TPICO EN PCC AIRFOILS SA DE CV. LAS GRFICAS FUERON OBTENIDAS DE CFE. 22. FACTURACIN ANTERIOR PCC AIRFOILS SA DE CV 23. FACTURACIN ACTUAL PCC AIRFOLIS SA DE CV