SUPER SPAN Alcantarillas
Transcript of SUPER SPAN Alcantarillas
-
MODELO LUZ LUZ EN FLECHA AREA PERIMETRO RADIO DEm BASE m m2 N TAPA
m m
238A5 5.91 5.83 2.06 9.75 33 3.99238A6 6.11 6.05 2.28 11.19 35 3.99258A6 6.56 6.50 2.36 12.39 37 4.34268A6 6.78 6.72 2.40 13.01 38 4.52278A6 7.01 6.94 2.44 13.65 39 4.69
288A6 7.23 7.17 2.49 14.29 40 4.86298A6 7.46 7.39 2.53 14.95 41 5.04308A6 7.68 7.62 2.57 15.62 42 5.21318A6 7.91 7.84 2.61 16.30 43 5.39318AB 8.31 8.26 3.04 20.11 47 5.39
338A7 8.56 8.50 2.91 19.68 47 5.74338A8 8.76 8.71 3.12 21.71 49 5.74348A7 8.78 8.73 2.95 20.45 48 5.91368A7 9.23 9.17 3.03 22.03 50 6.26368AB 9.43 9.38 3.24 24.20 52 6.26
378A7 9.45 9.40 3.07 22.84 51 6.44368A10 9.63 9.50 3.69 28.69 56 6.26398A7 9.68 9.62 3.11 23.66 52 6.61378A10 9.85 9.72 3.74 29.65 57 6.44388A10 10.08 9.95 3.78 30.62 58 6.61
398A8 10.10 10.06 3.37 26.81 55 6.79398A11 10.50 10.38 4.03 34.09 61 6.79418A8 10.55 10.51 3.45 28.60 57 7.13428A8 10.78 10.73 3.49 29.52 58 7.31418A14 11.55 11.46 4.76 44.30 69 7.13
428A14 11.77 11.69 4.80 45.51 70 7.31
NOTAS: Las dimensiones (dimetro luz flecha rea) son tomadas a la cresta interna dela corrugacin.
Son disponibles bajo pedido tamaos mayores e intermedios Para determinar la periferia total en metros multiplicar el valor N por 0.2438 Las longitudes de las estructuras son valores mltiplos de 6 y 8 pies. La altura de la cobertura mxima no dependegeneralmente de las condicionesde carga viva.
El diseo estructural deber tomar en cuenta las cargas vivas cuando:- Carreteras:altura de cobertura menor de 2.5 m- Vas frreas: altura de cobertura menor de 9.0 m
Paracargas vivas E-80 o equivalente, duplicar las alturas de cobertura mnima Las alturas de cobertura son calculadas segn metodologa de diseo de la AISI
CORRUGA
LUZ
~~ii
I ~ ILUZ EN BASE
VIGA DE EMPUJESon elementos de concreto armado que se vacian a unaaltura predeterminada a ambos lados y a todo lo largo delas estructuras Super Span. Se unen a la estructura pormedio de conectores y refuerzos de acero.
VARIA VARILLALONGITUDINAL
EL REFUERZONECESARIOVARIADE ACUERDO ALMODELO DEESTRUCTURAMP152S
I
PLANCHASLATERALE!ESL--- __ 'Io:\.
CANAL DE ARRANQUELos arcos Super Span se arman sobre muros de arranquede concreto que se unen a las estructuras por medio decanales de arranque en forma de "J".
CANAL DEARRANQUE
PLANCHADE ACERO
ESPECIFICACIONES TCNICAS:Las estructuras Multiplate y Super Span cumplen lasnormas internacionales AASHTOM-167 ASTM A-761.Son galvanizadas en caliente con un recubrimiento de Znde 610 gr/m2 de acuerdo a ASTMA-123.
-
MODELO LUZ LUZ EN FLECHA AREA PERIMETRO RADIO DEMAXIMA BASE m m2 N TAPA
m m m.
23SA5-3 6.11 5.96 2.77 14.12 39 3.9923SA6-6 6.31 5.74 3.68 19.85 47 3.9925SA5-6 6.56 6.04 3.55 19.93 47 4.3426SA5-6 6.78 6.28 3.59 20.85 48 4.5225SA7-8 6.96 6.05 4.42 26.40 55 4.34
26SA6-8 6.98 6.11 4.26 25.54 54 4.5227SA5-6 7.01 6.52 3.64 21.77 49 4.6928SA5-6 7.23 6.77 3.68 22.71 50 4.8627SA7-8 7.41 6.57 4.52 28.70 57 4.6929SA5-8 7.46 6.67 4.18 26.78 55 5.04
30SA5-7 7.68 7.10 4.00 26.27 54 5.2129SA7-8 7.86 7.07 4.61 31.03 59 5.0431SA5-7 7.91 7.34 4.04 27.31 55 5.3930SA7-8 8.08 7.32 4.65 32.22 60 5.2131SA7-8 8.31 7.57 4.70 33.41 61 5.39
33SA5-7 8.36 7.82 4.13 29.41 57 5.7434SA5-8 8.58 7.91 .4.40 32.31 60 5.9133SAB-8 8.96 8.26 5.00 38.24 65 5.7434SA8-10 9.18 8.15 5.49 43.27 70 5.9136SA6-8 9.23 8.59 4.70 37.04 64 6.26
37SA6-8 9.45 8.84 4.74 38.26 65 6.4436SA8-10 9.63 8.65 5.58 46.11 72 6.2637SA7-10 9.65 8.70 5.41 44.85 71 6.4438SA6-10 9.68 8.75 5.24 43.56 70 6.6137SA8-12 9.85 8.50 6.07 51.40 77 6.44
39SA6-10 9.90 9.00 5.29 44.92 71 6.7938SA8-12 10.08 8.76 6.12 52.98 78 6.6139SA8-12 10.30 9.02 6.16 54.57 79 6.7941SA6-10 10.35 9.49 5.37 47.67 73 7.1341SA7-12 10.55 9.33 6.04 54.79 79 7.13
42SA6-10 10.58 9.74 5.42 49.07 74 7.3141SA8-13 10.75 9.32 6.47 59.85 83 7.1342SA7-12 10.78 9.58 6.08 56.36 80 7.3142SA8-13 10.98 9.58 6.52 61.54 84 7.3141SA11-13 11.35 9.92 7.11 69.28 89 7.13
42SA11-13 11.57 10.18 7.16 71.11 90 7.31
ESPECIFICACIONES TCNICAS:Las estructuras Multiplate y Super Span cumplen las normas internacionalesAASHTO M-167 ASTM A-761. Son galvanizadas en caliente con unrecubrimiento de Zn de 610 gr/m2 de acuerdo a ASTM A-123.
CORRUGA
LUZ
-e::J:(,)W....1LL
~ 'ReVIGA DE ""'-EMPUJE
~RI
LUZ EN BASE
VIGA DE EMPUJESon elementos de concreto armado que se vacian a unaaltura predeterminada a ambos lados y a todo lo largo delas estructuras Super Span. Se unen a la estructura pormedio de conectores y refuerzos de acero.
VARIA VARILLALONGITUDINAL
EL REFUERZO
NECESARIOVARIADE ACUERDO ALMODELO DEESTRUCTURAMP152S
CANAL DE ARRANQUELos arcos Super Span se arman sobre muros de arranquede concreto que se unen a las estructuras por medio decanales de arranque en forma de "J".
CANAL DE
ARRANQUE
...CIMENTACION DE CONCRETO PARA ESTRUCTURA ARCO
NOTAS:
Las dimensiones (dimetro, luz, flecha, rea) son tomadas a la crestainterna de la corrugacin
Son disponibles bajo pedido tamaos mayores e intermedios Para determinar la periferia total en metros multiplicar el valor N por
0.2438 Las longitudes de las estructuras son valores mltiplos de 6 y 8 pies. La altura de la cobertura mxima no depende generalmente de las
condiciones de carga viva. El diseo estructural deber tomar en cuenta las cargas vivas cuando:
- Carreteras: altura de cobertura menor de 2.5 m- Vas frreas: altura de cobertura menor de 9.0 m
Para cargas vivas E-80 o equivalente, duplicar las alturas de coberturamnima
Las alturas de cobertura son calculadas segn metodologa de diseo delaAISI